PGE11 Extended Optical Point Gas Detector for Hydrocarbons & CO₂
Optronics

PGE11 Extended Optical Point Gas Detector for Hydrocarbons & CO₂

Long optical path for increased sensitivity, in three lengths

Extended version of the PG11 explosion-proof infrared point detector. Its longer optical path increases sensitivity, and it comes in 15, 35, or 50 cm lengths for duct, pipe, and double-wall pipe mounts. It has the same lifetime factory calibration, T90 under 1.5 seconds, and SIL 2 design as the PG11.

ATEXIECExSIL 2MEDDNV
Contact GDS for current pricing, availability, and lead time. Available configurations may vary by application.
Manufacturer
Optronics
Category
Infrared Point Gas Detectors
Mounting
Fixed
Gas / hazard
Hydrocarbons, Methane, LEL, CO₂
Approvals
ATEX, IECEx, SIL 2, MED, DNV
Typical applications
LNG / Natural Gas, Offshore, Refineries, Petrochemical, Manufacturing / Processing

Why customers choose this product

A long optical path increases sensitivity for HVAC intakes, gas turbine enclosures, double-wall (double-skin) LNG/LPG pipe, and other applications that need early warning.

Comes in three lengths: short (15 cm), medium (35 cm), and long (50 cm), to fit different duct, pipe, and enclosure installations.

Factory calibrated for life, so there is no field calibration. Built-in condition monitoring runs a continuous health check and tells the operator when anything needs attention.

The solid-state infrared SafeSource™ carries a 15-year warranty, and the detector has a 6-year warranty. T90 is under 1.5 seconds, with OptoBAS™ baseline accuracy and heated sapphire optics.

Designed for SIL 2/SC3 systems (SIL 3 in 1oo2 redundancy) and rated ATEX/IECEx Ex db eb ib IIC T5 Gb, with marine approvals from MED, BV, LR, DNV GL, and ABS.

4–20 mA source or sink output with HART 7, plus the OptoCom™ module for application-specific digital protocols and DCS integration.

Typical applications

From the PGE11 datasheet (022-80102-ML R02). Contact GDS for help with application and positioning.

HVAC

Duct-mounted detection in air intakes and ventilation systems.

Gas turbines

Combustible gas detection in turbine enclosures and ventilation ducts.

Double-wall pipe

Monitoring of double-wall (double-skin) LNG and LPG pipe.

Increased sensitivity

Any application where a longer optical path gives earlier warning.

Configurations

The PGE11 comes in three lengths.

Short

15 cm

Medium

35 cm

Long

50 cm. Reduced vibration range; contact GDS for details.

Gases and measuring ranges

Methane

0–100% LEL, or 0–100% by volume

Propane, ethylene, butane

0–100% LEL

Biogas

0–100% by volume (CH₄ in a CO₂ background)

Carbon dioxide (CO₂)

0–100% by volume

Accessories

Contact GDS to specify.

Duct flange kit

For most standard JIS, DIN, and ANSI flanges.

Gas test kit

For field testing. Available in lengths to match each PGE11 version.

Universal mount kit

Fits most existing installation footprints to simplify retrofits. A pole mount kit with U-bolts for 3 in. and 4 in. poles is also available.

Remote gas test kit

A test point you route to the detector with standard tubing or piping, for detectors in inaccessible or remote locations.

Documentation

Manufacturer datasheet with specifications, accessories, and typical applications.

Where it's used

Typical facilities and process areas where this product protects people and assets.

LNG / Natural Gas
Offshore
Refineries
Petrochemical
Manufacturing / Processing

Technical specifications

Key parameters below. For full datasheets, ratings, and ordering options, contact GDS.

ManufacturerOptronics
CategoryInfrared Point Gas Detectors
TechnologySolid-state infrared SafeSource™, temperature compensated; long optical path for increased sensitivity
Gases and rangesMethane 0–100% LEL or 0–100% vol · Propane, ethylene, butane 0–100% LEL · Biogas (CH₄ in CO₂) 0–100% vol · CO₂ 0–100% vol
ConfigurationsShort 15 cm · Medium 35 cm · Long 50 cm (reduced vibration range)
CalibrationFactory calibrated; no field calibration needed
Self-testContinuous health check of all important hardware and software functions
Accuracy±3% FS
Repeatability±1% FS
Response timeT90 = 1.5 s
Signal output4–20 mA current source or sink; warnings and faults signalled below 4 mA · HART 7 for maintenance and configuration · OptoCom™ for application-specific digital protocols
Operating temperature−40 to +65 °C (−40 to +149 °F) · Desert version −40 to +75 °C (−40 to +167 °F) · Arctic version −60 to +65 °C (−76 to +149 °F)
Storage temperature−60 to +75 °C (−76 to +167 °F)
Humidity0–100% RH
VibrationResistant to shock and vibration up to 4 g (reduced range on the long version)
Ingress protectionIP66 / IP67
Housing316L stainless steel
Weight and dimensionsUnder 4 kg (8.8 lb); 775 × 120 × 120 mm
Field wiringStranded or solid wire up to 2.5 mm²
Cable entriesTwo M20 as standard; M25, ½" NPT, and ¾" NPT on request
Power18–50 V DC; under 3.5 W average (under 5 W, Arctic version); soft boot with 1 A max. current spikes
Hazardous areaATEX/IECEx Ex db eb ib IIC T5 Gb
Marine approvalsMED, BV, LR, DNV GL, ABS
Safety integritySIL 2/SC3 to IEC 61508 (SIL 3 in 1oo2 redundancy)
Warranty6 years; 15 years on the SafeSource™
ApprovalsATEX, IECEx, SIL 2, MED, DNV

Add this product to a quote request

Tell us the details and we'll come back with pricing, availability, and lead time — usually the same day.

Related products

Others in the Infrared Point Gas Detectors range and from Optronics.

Request pricing & availability

Send us the details and our team will get you a quote and lead time — usually the same day.

Request a Quote